Boiler Water Treatment Chemicals
Zyax supplies boiler water treatment chemicals that protect steam boilers from scale, corrosion and carryover: oxygen scavengers, condensate line amines, scale and sludge conditioners, and descaling chemicals with corrosion inhibitors for cleaning. Clean, protected boilers use less fuel and fail less often.
- Manufacturer & supplier, Mumbai
- Send your water report, get a product recommendation
- Bulk packs, delivered across India
- Range
- Carbohydrazide, DEHA, hydrazine hydrate, sodium sulphite and SMBS, morpholine, cyclohexylamine, HEDP, PBTC, ATMP, boiler descalant, acid corrosion inhibitors
- Used in
- Fire-tube and water-tube steam boilers, hot water generators, condensate systems, food, textile, pharma, chemical, sugar and paper plants
- Forms
- Liquids and powders in cans, drums and bags
- How we help
- Share your boiler type, pressure, feed water and boiler water analysis; we suggest a programme
Why boiler water needs treatment
Even softened or RO water carries small amounts of hardness, silica, dissolved oxygen and carbon dioxide. Inside a boiler these cause three expensive problems:
- Scale: hardness and silica deposit on tubes. Scale insulates the metal, so more fuel is needed for the same steam, and tubes can overheat and fail.
- Corrosion: dissolved oxygen causes pitting in the boiler and feed system; carbon dioxide forms carbonic acid that eats condensate lines.
- Carryover: high dissolved solids, oil or foaming carry boiler water into the steam, contaminating process and damaging equipment.
Our boiler chemical range
| Product | What it does | Notes |
|---|---|---|
| Carbohydrazide (liquid and powder) | Oxygen scavenger and metal passivator | A widely used alternative to hydrazine |
| DEHA (diethylhydroxylamine) | Volatile oxygen scavenger that also protects condensate lines | Travels with steam |
| Hydrazine hydrate 80% | Oxygen scavenger for high-pressure boilers | Hazardous and a suspected carcinogen; strict handling controls; never for steam that touches food or medicines |
| Sodium sulphite / SMBS | Economical oxygen scavenger for low and medium pressure boilers | Adds dissolved solids |
| Morpholine | Neutralising amine; raises condensate pH to stop carbonic acid corrosion | Volatile, follows the steam |
| Cyclohexylamine | Neutralising amine for longer condensate systems | Often blended with morpholine |
| HEDP, PBTC, ATMP (phosphonates) | Scale inhibitors and sequestrants | Used in low-pressure boiler programmes and cooling water; they break down at higher pressures |
| Phosphate and polymer conditioners | Keep hardness as soft, removable sludge instead of hard scale | Removed through regular blowdown |
| Boiler descalant | Removes scale during shutdown cleaning | Used with an acid corrosion inhibitor |
| Acid corrosion inhibitors (for hydrochloric, sulphamic and citric acid cleaning) | Protect boiler metal while acid dissolves scale | Essential for safe acid cleaning |
| Glycol corrosion inhibitor | Protects closed loops and chilled water systems using glycol |
A typical boiler treatment programme
- Good feed water: softener or RO to remove most hardness. See softener resins and salt and RO chemicals.
- Remove oxygen: deaerator or hot well plus an oxygen scavenger such as carbohydrazide, DEHA or sulphite.
- Control scale and sludge: a phosphate, chelant or polymer conditioner suited to your boiler pressure, with regular blowdown to keep dissolved solids in range.
- Protect condensate lines: a neutralising amine such as morpholine or cyclohexylamine.
- Test and adjust: check pH, TDS, hardness, alkalinity and scavenger residual regularly and log the results.
Boiler descaling done safely
When scale has already built up, the boiler is cleaned during shutdown with a descaling acid. Acids attack steel as well as scale, so an acid corrosion inhibitor is always added to protect the metal. After descaling, the system is neutralised, rinsed and passivated before restart. Descaling should be planned with the boiler maker's guidance and done by trained people with proper protective equipment.
Who uses our boiler chemicals
- Textile and dyeing
- Food processing and dairies
- Pharmaceuticals
- Chemicals and dyes
- Sugar and distilleries
- Paper and packaging
- Rubber and tyre
- Hotels, hospitals and laundries
- Rice mills and solvent extraction
- Boiler AMC contractors
Grades and specifications
Typical values for each grade we supply. Technical data sheet and safety data sheet available on request.
Zyax ZYSTEAM 110Boiler antiscalant
Stops hardness salts precipitating on heat transfer surfaces.
| HS code | 38249022 |
|---|
Zyax ZYSTEAM 210Boiler corrosion inhibitor
Combined scale and corrosion inhibitor for boilers, hot water systems and steam plants.
| HS code | 38249022 |
|---|
Zyax ZYSTEAM 310Sludge conditioner
Keeps sludge fluid for removal by blowdown; also for boiler water contaminated with oil. Low and medium pressure boilers.
| HS code | 38249022 |
|---|
Zyax ZYSTEAM 410Alkalinity builder and pH booster
Controls boiler water pH and alkalinity to protect feed tanks, lines and pumps.
| HS code | 38249022 |
|---|
Zyax ZYSTEAM 610Fireside chemicals
Combustion catalysts, slag modifiers and dust suppressants for solid-fuel boilers.
| HS code | 38249022 |
|---|
Boiler Water Treatment Chemicals: product range
Each product line has its own page with uses, dosing guidance and FAQs.
- Carbohydrazide Oxygen Scavenger
- DEHA (Diethylhydroxylamine)
- Hydrazine Hydrate 80%
- Sodium Sulphite for Boilers
- Neutralising Amines (Morpholine and Cyclohexylamine)
- Boiler and Cooling System Descalants
Frequently asked questions
What chemicals are used in boiler water treatment?
Common boiler chemicals are oxygen scavengers (carbohydrazide, DEHA, sulphite), neutralising amines for condensate lines (morpholine, cyclohexylamine), scale and sludge conditioners (phosphate, chelant or polymer programmes, with phosphonate blends for low-pressure boilers), and alkalinity builders. Descaling acids with corrosion inhibitors are used for cleaning.
What is an oxygen scavenger in a boiler?
An oxygen scavenger is a chemical that reacts with dissolved oxygen in boiler feed water. Removing oxygen prevents pitting corrosion, one of the most common causes of boiler tube failure.
Carbohydrazide or hydrazine: which is better?
Both remove oxygen and help passivate metal. Carbohydrazide is widely used as a replacement for hydrazine because it is considered safer to handle. Your choice depends on boiler pressure and steam use. Where steam touches food, drinks or medicines, use only scavengers and amines approved for that use, within their limits; hydrazine and carbohydrazide are not suitable for such steam. Ask us before choosing.
What is DEHA used for in boilers?
DEHA (diethylhydroxylamine) is a volatile oxygen scavenger. Because it travels with the steam, it also protects condensate and return lines from oxygen corrosion.
Why use morpholine in a boiler?
Morpholine is a neutralising amine. It vaporises with the steam and raises the pH of condensate, preventing carbonic acid corrosion in steam and return lines.
How does scale affect boiler fuel consumption?
Scale acts as an insulating layer on the tubes, so more fuel is needed to transfer the same heat, and tubes run hotter. Keeping tubes clean protects both fuel efficiency and tube life.
Can I descale a boiler with acid?
Yes, boilers are commonly descaled with acid during shutdown, but always with an acid corrosion inhibitor and following the boiler maker's guidance, with proper neutralisation and rinsing afterwards.
What details do you need to recommend boiler chemicals?
Boiler type and pressure, steam output, feed water source and treatment, and recent feed water and boiler water analysis (pH, TDS, hardness, alkalinity). You can WhatsApp a photo of your log sheet.
Get a quote for boiler water treatment chemicals
Tell us what you are treating and how much you use. Send your water or effluent analysis if you have one, and we will recommend the right product and pack size.
Related water treatment products

Cooling Tower Chemicals
Scale and corrosion inhibitors, biocides and descalants for cooling water.

Ion Exchange Resins & Softener Salt
Softener and DM plant resins, and salt for regeneration.

RO Antiscalants & Membrane Cleaners
Stop scaling and fouling in RO plants; clean and restore membranes.

Filter Media
Iron and manganese removal media, activated alumina, anthracite, quartz sand and gravel.
Recognized by Leading Industry Publications