Water Treatment Chemical Dosing Calculator
Three free calculators for plant operators and buyers: how many kg of chemical you need a day and a month from your flow and ppm dose, how much polyelectrolyte powder to put in a solution tank, and your cooling tower cycles of concentration and blowdown.
- Manufacturer & supplier, Mumbai
- Send your water report, get a product recommendation
- Bulk packs, delivered across India
1. Chemical consumption calculator
Enter the water flow, the dose of active chemical (in mg/L, the same as ppm) and the strength of the product you buy. The calculator shows how much product you will use.
2. Polyelectrolyte solution calculator
Polyelectrolyte powder is dissolved to a dilute solution before dosing. Enter the tank size and the strength you want.
3. Cooling tower cycles and blowdown calculator
Compare the conductivity (or TDS, or chloride) of the tower water with the make-up water to find the cycles of concentration. Add the circulation rate and temperature drop to estimate evaporation and blowdown.
How the dose calculation works
A dose of 1 mg/L (1 ppm) in 1 m³ of water is 1 gram of chemical. So the active chemical needed per day is:
kg per day = water treated (m³/day) × dose (mg/L) ÷ 1,000
If the product is not 100% active, divide by its strength. For example, 3 ppm of active chemical in 200 m³/day is 0.6 kg a day of active; with a 50% product that is 1.2 kg a day of product.
The right dose for your plant depends on your water and the product. If you do not know it, send us your water report and we will suggest a starting dose.
Frequently asked questions
How do I convert ppm to kg per day?
Multiply the water flow in m3 per day by the dose in ppm (mg/L) and divide by 1,000. That gives kg per day of active chemical. Divide by the product strength (as a fraction) to get kg of product.
Is ppm the same as mg/L?
For water and dilute solutions, 1 ppm is effectively the same as 1 mg per litre.
How do I calculate polyelectrolyte solution strength?
Powder needed in kg = tank volume in litres x strength in % / 100. For a 0.2% solution in a 500 litre tank, add 1 kg of powder.
How are cycles of concentration calculated?
Divide the conductivity, TDS or chloride of the cooling tower water by that of the make-up water. For example, 1,600 divided by 400 gives 4 cycles.
How is cooling tower blowdown calculated?
Blowdown plus drift is roughly evaporation divided by (cycles minus 1). Evaporation can be estimated as 0.00153 x circulation rate (m3/hr) x temperature drop (degrees C).
What dose of chemical should I use?
The dose depends on your water and the product. Send us your water report and plant details and we will recommend a starting dose.
Get a quote for water treatment chemicals
Tell us what you are treating and how much you use. Send your water or effluent analysis if you have one, and we will recommend the right product and pack size.
Related water treatment products

Polyelectrolyte Flocculants & Coagulants
Cationic and anionic polyelectrolytes, PolyDADMAC and polyamines for clarification and sludge dewatering.

Cooling Tower Chemicals
Scale and corrosion inhibitors, biocides and descalants for cooling water.

RO Antiscalants & Membrane Cleaners
Stop scaling and fouling in RO plants; clean and restore membranes.

Poly Aluminium Chloride (PAC) & Alum
Fast-acting coagulants for drinking water, ETPs and STPs.
Recognized by Leading Industry Publications